SPAN ADJUST

Span adjust allows the user to tweak the span of the entire scale at once.
Press 4 and ENTER.
1.
The 225D will display the current live scale weight "SCALE WT = XXXXX.X".
2.
NOTE: High-resolution weight (interval/10) will be shown if the weight interval setting is
less than 10. For example, an interval of 5 will be shown in 0.5 increments.
Note that high-resolution weight (interval/10) will be shown if the weight interval setting
3.
is less than 10. For example, an interval of 5 will be shown in 0.5 increments.
Place the test weight at any location on the scale.
4.
Press SET_WT soft key. The 225D will prompt "ENTER NEW WEIGHT = ".
5.
Enter the value of the test weight and press ENTER.
6.
The 225D will adjust the span to target weight.
7.
16