MAGIQCOOL CONTROL OPERATION

CONTROL PARAMETERS

A number of Control Parameters can be set to alter the
operation of the cooler.
Changing Control Parameters
To enter Parameter mode using a Wall Control, the
following process must be carried out within Four (4)
minutes of mains power being applied to the cooler. If
unsure of time since the last Mains Power "ON", remove
Mains Power to the cooler (Isolator Switch or Circuit
Breaker) for a minimum of six (6) seconds so the mode
can be entered.
Whilst the wall control is OFF, push and hold "
1.
for minimum of three (3) seconds. After three (3)
seconds whilst still holding "
"
" button. (If "
three (3) seconds, nothing will be on the display. If
"
" button is continued to be held, subsequent
presses of "
" button will allow access).
When parameter mode has been entered, the screen
2.
will display "A1" and "Param". Pressing "
"
" buttons will scroll through parameters "A1" to
"B3" (Refer to table below for factory settings).
To view the parameter value set in the wall control
3.
press "
" momentarily. Figure "A#" on screen
will change to number set, and "Param" will change to
"value".
To alter the "value" of the selected parameter press
4.
"
" or "
". Numbers will change to show the
different values the parameter can be set to.
To store the selected value, press "
5.
screen will go blank momentarily as the wall control
stores the parameter change, and returns the screen
to "A#" and "Param".
6. To exit parameter mode or escape from an alteration
without storing a change press "
instead of "
" button. Remember, once step five
(5) has been carried out, new parameter change is
permanent until again altered.
7. If no buttons are pushed on wall control, after three
(3) minutes the screen will reset to "OFF" state. The
procedure to enter parameter mode must be re-
initiated.
No. DESCRIPTION
A1
Water salinity control method:
- Conductivity measuring
- Counts low to high probe fills
A2
Not applicable to CW-P15
A3
Pre-wet control:
- No pre-wet
- Pre-wet
A4
Wall Control back light:
- Backlight 'OFF'
- Backlight 'ON'
A5
Conductivity set point:
- Normal conductivity - 4275 µS/cm
- Low conductivity - 2305 µS/cm
A6
Tank (reservoir) drain delay:
- Instant drain at COOL off
- Drain 3 hours after COOL off
- Drain 12 hours after COOL off
- Drain 3 days after COOL off
A7
Auto re-start after Power failure:
- Manual re-start when power OFF
- Auto restart
A8
Temperature units:
- Display 0°C
- Display 0°F
* = Default Value
" button press the
" button is pressed before
" or
". The
" button
VALUE
00*
01
00
01*
00
01*
00*
01
00
01
02
03*
00*
01
00*
01

WALL CONTROL OPERATION

Turning Cooler On

The wall control can be switched on and off by pressing
the "
" button. The wall control will remember the
previous setting it was in when the cooler was last used.
Preparing to Start
Whenever you select AUTO mode, or COOL in MANUAL
mode, the cooler will take a few minutes to start as it fills
with water and saturates the cooling pads. The time will
be decreased if the reservoir is full or the cooler has only
recently been turned OFF.
"

Manual Mode

With the wall control switched ON, press the "
button until MAN is shown on the display. (Note: The
Wall control display will default to show temperature in
deg C (Celsius). If deg F (Fahrenheit) is desired, refer
to previous table for instructions on how to change the
A8 Temperature Unit parameter). Although the indoor
temperature will be displayed, in manual mode the cooler
will not be controlling the temperature.
Man
Cool
You may then press the "
button to switch between COOL
and VENT
(VENT = fresh air being
delivered but not cooled).
Once COOL or VENT has been
selected, the wall control will
maintain a constant fan speed.
This is indicated by the bar graph
shown on the display.
To increase or decrease the fan speed required, press
either the "
" or "

Auto Mode

To select the AUTO mode
press the "
" button until
AUTO is shown on the display.
In AUTO mode the cooler will
remember the last setting used
and try to achieve this. Pressing
"
" or "
" button will
change the displayed 'room'
temperature to a flashing
'setpoint' temperature.
SEELEY INTERNATIONAL - INSTALLATION MANUAL CW-P15 859740-G |
Man
Cool
F
"
ILL1707-A
Man
Vent
" button.
Auto
Cool
"
ILL1709-A
ILL1708-A
ILL1710-A
16