Replace The Circulation Pump - Seeley Climate Wizard CW-P15 Installation Operation & Maintenance

Indirect evaporative cooler
Table of Contents

Advertisement

MAINTENANCE INSTRUCTIONS
• Remove any cable ties that bundle the excess cable length.
• From the inlet side of the cooler, pull the cable through the
conduit.
• From the electronics enclosure side of the cooler, feed an
electrician's cable chasing snake through the conduit.
• Tape the terminals of the replacement drain pump to the cable
snake and pull through to the electronics enclosure.
• Thread the new cable through the cable gland and plug the
terminals into the PCBA.
• Re-assemble the drain pump pipe and holding plate and
secure any excess cable length with cable ties.
• Replace the electronics cover and restore mains power to
cooler.
|
CW-P15 Indirect Evaporative Cooler 859740-G
29

REPLACE THE CIRCULATION PUMP

Purpose:
To replace a faulty circulation pump
Method:
• Turn off Power to the cooler.
• Remove the utilities cover to gain access to the inside of the
housing.
ILL3577-A
ILL3577-A
• Remove the pump access cover at the front of the cooler.
ILL3578-A
ILL3578-A
• Remove the horizontal rubber hose attached to the circulation
pump.
ILL3579-A
ILL3579-A
• Unscrew the single screw attaching the circulation pump to a
tab on the aluminium chassis.
• Slide the circulation pump spigot out of the rubber collar in the
cooler tank.
ILL3580-A
ILL3580-A
ILL3581-A
ILL3581-A
ILL3582-A
ILL3582-A
ILL3583-A
ILL3583-A