CDA Equipment Troubleshooting (continued)
CDA spins slowly.
CDA spins too fast
and lamp does not
glow.
Pump/CDA operates
intermittently.
Pump will not operate.
Pump runs but no flow
from outlet.
Pump runs but no flow
from outlet.
Table 11 - CDA Troubleshooting
1
Refer to your tank system instructions.
Your tank system must include an inline filter of 50 mesh size (blue – ISO19732).
Troubleshooting
Moisture or corrosion
in the motor.
Incorrect wattage
globe.
Incorrect wattage
globe.
Globe wiring
reversed.
Loose electrical
connection.
Pump wire not
connected to
backplate.
Loose electrical
connection.
Diode faulty.
Diode polarity
incorrect.
Faulty pump motor.
Incorrect wiring.
Tank empty.
Blocked restrictor.
Blocked nozzle.
Blocked filter.
Blocked hose.
Kinked hose.
Float stuck in flow
meter.
Solenoid not opening.
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser
Replace motor.
Replace globe.
Replace globe.
Check and rewire.
Check all
connections; tighten
as necessary.
Connect to Backplate
2 pin panel socket.
Check all
connections; tighten
as necessary.
Replace diode.
Reverse diode
connections.
Replace pump motor.
Check wiring and
rewire as necessary.
Refill tank.
Clean restrictor in
control unit feed tube.
Remove and clean
nozzle.
Check and clean all
1
filters.
Purge all hoses.
Straighten all hoses.
Gently loosen the
float and clean the
flow meter.
Check wiring; replace
the solenoid if
necessary.