5.3

Calculating the Tree Length (Km) Sprayed Per Tank Fill

Tree length sprayed (km) =
10 x Tank Contents (L) / (Application Rate l/ha x Band treated m)
For Example:
2 x Undavina 400 = 0.8 m band
Tank contents = 80 l
Application rate = 40 l/ha
Tree length sprayed (km) = 10 x 80 litre / (40 l/ha x 0.8 m) = 25 km
5.4

Calculating Mixing Rates

Read the safety instruction at the beginning of this document before
handling chemicals. Always carefully read and follow the handling
instructions supplied by chemical manufacturer.
Wear Gloves
ALWAYS read the product label to identify the maximum quantity of product to be
applied per hectare e.g. 2 litres product per hectare.
Calculate the total volume of spray mix required as follows
Spray Mix Volume (litres) =
Volume Rate (l/ha) x Band Width (metres) x Field Area (ha) / Row Width (metres)
Volume Rate (l/ha):
Band Width (metres):
Field Area (ha):
Row Width (metres):
Calibration
Wear a face shield
or Eye Protection
This is the total amount of spray mix to be sprayed on the
treated area.
This is the width covered by the shield or combination of
shields.
This is the total area of field.
This is the distance between tree or crop rows.