Using a small screwdriver carefully prise the sealing ring out of the bayonet cap.
Take care to avoid damaging the seal. Not applicable where a brass nozzle body
is fitted.
Inspect the seal for any damage. If the seal is marked or damaged or has become
hard or cracked it should be replaced. Not applicable where a brass nozzle body
is fitted.
The nozzle tip is a sliding fit into the bayonet cap / brass retaining nut. Turn the
bayonet cap / brass retaining nut over with the open end downwards and the
nozzle should fall out.
To clean the nozzle tip use a soft bristled brush or toothpick do not use a metal
object or wire brush. Use extreme care with soft tip materials such as plastic as
even a wooden toothpick may distort the orifice.
Refitting of the nozzle is a reversal of the above procedure. Ensure all components
are clean before refitting. Do not over tighten brass retaining nut as this may damage
the nozzle.
Maintenance
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser
49