Table 6 – Flow rates (l/min per nozzle) – Spraymiser Hi Flo
Calibration
Volume Rate
50
l/ha
Vehicle Speed kph
Band m
3
4
5
6
1.20
0.15
0.20
0.25
0.30
1.50
0.19
0.25
0.31
0.38
1.80
0.15
0.20
0.25
0.30
2.00
0.17
0.22
0.28
0.33
2.40
0.15
0.20
0.25
0.30
Volume Rate 100 l/ha
Vehicle Speed kph
Band m
3
4
5
6
1.20
0.30
0.40
0.50
0.60
1.50
0.38
0.50
0.63
0.75
1.80
0.30
0.40
0.50
0.60
2.00
0.33
0.44
0.56
0.67
2.40
0.30
0.40
0.50
0.60
Volume Rate 150 l/ha
Vehicle Speed kph
Band m
3
4
5
6
1.20
0.45
0.60
0.75
0.90
1.50
0.56
0.75
0.94
1.13
1.80
0.45
0.60
0.75
0.90
2.00
0.50
0.67
0.83
1.00
2.40
0.45
0.60
0.75
0.90
Volume Rate 200 l/ha
Vehicle Speed kph
Band m
3
4
5
6
1.20
0.60
0.80
1.00
1.20
1.40
0.70
0.93
1.17
1.40
1.80
0.60
0.80
1.00
1.20
2.00
0.67
0.89
1.11
1.33
2.40
0.60
0.80
1.00
1.20
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser
Volume Rate
8
10
12
3
0.40
0.50
0.60
0.23
0.30
0.50
0.63
0.75
0.28
0.38
0.40
0.50
0.60
0.23
0.30
0.44
0.56
0.67
0.25
0.33
0.40
0.50
0.60
0.23
0.30
Volume Rate 125 l/ha
8
10
12
3
0.80
1.00
1.20
0.38
0.50
1.00
1.25
1.50
0.47
0.63
0.80
1.00
1.20
0.38
0.50
0.89
1.11
1.33
0.42
0.56
0.80
1.00
1.20
0.38
0.50
Volume Rate 175 l/ha
8
10
12
3
1.20
1.50
1.80
0.53
0.70
1.50
1.88
2.25
0.66
0.88
1.20
1.50
1.80
0.53
0.70
1.33
1.67
2.00
0.58
0.78
1.20
1.50
1.80
0.53
0.70
Volume Rate 250 l/ha
8
10
12
3
1.60
2.00
2.40
0.75
1.00
1.87
2.33
2.80
0.88
1.17
1.60
2.00
2.40
0.75
1.00
1.78
2.22
2.67
0.83
1.11
1.60
2.00
2.40
0.75
1.00
Consider lower volume rates if possible.
Hi Flo nozzle
CDA only
< Flow too low
75
l/ha
Vehicle Speed kph
4
5
6
8
10
12
0.38
0.45
0.60
0.75
0.90
0.47
0.56
0.75
0.94
1.13
0.38
0.45
0.60
0.75
0.90
0.42
0.50
0.67
0.83
1.00
0.38
0.45
0.60
0.75
0.90
Vehicle Speed kph
4
5
6
8
10
12
0.63
0.75
1.00
1.25
1.50
0.78
0.94
1.25
1.56
1.88
0.63
0.75
1.00
1.25
1.50
0.69
0.83
1.11
1.39
1.67
0.63
0.75
1.00
1.25
1.50
Vehicle Speed kph
4
5
6
8
10
12
0.88
1.05
1.40
1.75
2.10
1.09
1.31
1.75
2.19
2.63
0.88
1.05
1.40
1.75
2.10
0.97
1.17
1.56
1.94
2.33
0.88
1.05
1.40
1.75
2.10
Vehicle Speed kph
4
5
6
8
10
12
1.25
1.50
2.00
2.50
3.00
1.46
1.75
2.33
2.92
3.50
1.25
1.50
2.00
2.50
3.00
1.39
1.67
2.22
2.78
3.33
1.25
1.50
2.00
2.50
3.00