The feed hose of Micron HiFlo models should be connected directly to a regulated
tank system output. Output flow rate will vary with pressure, number of nozzles and
nozzle size. For test purposes use clean water only. Place a suitable tray or vessel
below the spray nozzles. Start your spray pump and set your output pressure to 1.5
bar. Run the spray pump for one minute or until all the air is evacuated from the
system. Check that the output from the nozzles does not fluctuate. Dispose of
collected fluids responsibly refer to section 8.1 of this document. For further
instruction on setting the output flow rate refer to section 5 of this document.
CDA Systems
The feed hose of Spraydome/Undavina/Spraymiser CDA models is supplied pre
attached to the control unit.
 Connect the control unit feed tube to the back plate manifold (1).
 Connect the backplate feed hose (2) to your spray tank system. Any additional
control unit backplates can be connected together in series or parallel after the
spray pump. Larger installations where long hoses or multiple heads are used
may require multiple spray pumps to ensure consistent output.
 Set your spray tank outlet pressure to between 8 and 10 psi. For further
instruction on setting the output flow rate refer to the calibration section of
this document.
Installation
2
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser