CDA Nozzle
Micron CDA units are fitted with a rotary atomiser that is fed from the spray tank via a
colour coded feed nozzle. There are two types of atomiser assembly fitted to the
Spraydome/Undavina and Spraymiser, a disc type and a drum type.
9.2.1 Removing the Feed Nozzle (Drum Type Atomiser)
The following procedure describes the removal of the spray nozzle for the drum type
atomiser on the Spraydome/Undavina; on Spraymiser units the atomiser assembly
must first be removed from the spray shield refer to section 9.3.3.
Remove the small plastic elbow from the spray nozzle. Use a twisting motion to
ease the elbow from the feed nozzle. Take care not to damage the plastic
components.
Remove the plastic nozzle. Use a twisting motion to ease the feed nozzle from the
plastic cover. Take care not to damage the plastic components.
Refitting of the feed nozzle is a reversal of the above procedure. Ensure all
components are clean before refitting.