54
9.3.3 Removing Spraymiser CDA Atomiser Assembly
Remove the 4 screws that retain the CDA recess cover. Retain the screws and
cover for later refitting.
Disconnect the spray hose at the compression joint
Record the electrical connection orientation in the connector block for later
reassembly. Disconnect the motor electrical connections at the connection block.
Remove the 3 screws that retain the CDA atomiser assembly. Retain the screws
for later refitting. Remove the CDA atomiser assembly.
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser