Shield And Skirt Replacement; Fuse Replacement - Micron Spraydome Series Instruction Manual

Table of Contents

Advertisement

60
 Cut any cable ties used to retain the solenoid. Replacement cable ties are
available from Micron group or their agents.
 Disconnect the electrical connections that connect the solenoid to its terminal
block.
Refitting the
The solenoids on the Spraymiser units are attached to the chassis under the cover.
To access the solenoids first remove the Spraymiser from its mounting. Turn the unit
over to gain access to the solenoids.

9.10 Shield and Skirt Replacement

Spraydome and Undavina
Replacement brush skirts and domes are supplied as complete assemblies and
include new bearing assemblies.
 Disconnect the feed pipe at the elbow located above the shield bearing.
 Disconnect the electrical connections at the connector block (CDA only)
 Remove the large retaining nut above the shield bearing.
 Remove the shield assembly from the breakaway arm
 Remove the shield from the atomiser or hydraulic pressure nozzle assembly.
Refitting the shield is a reversal of the above procedure.
Some Undavina brush skirts are available as spare parts without the centre disc and
bearing. These are held in place by either nuts and bolts or rivets. For further
information on replacement of brush skirts refer to the parts catalogue for your
equipment or to Micron group or their agents.
Spraymiser Shields
For CDA follow the information in section 9.3.3 to remove the atomiser assemblies.
The Spraymiser shields are attached to the centre chassis or wing arms by a through
bolt and nut.
 Disconnect the hose and cable assembly (CDA only) or feed hose (Hi-Flo) from
all connections.
 Remove the hose and cable assembly (CDA) or feed hose (Hi-Flo) from the
shield.
 Remove any addition parts that are attached to, or pass through, the shield.
 Remove the retaining nut and bolts.
 Remove the shield complete with brush skirt.
Refitting the shield is a reversal of the above procedure.

9.11 Fuse Replacement

The standard power wire assembly for CDA units has an inline fuse fitted to the
positive (+) wire near to the positive (+) battery terminal.
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser
Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents