Flow Meter Replacement And Cleaning - Micron Spraydome Series Instruction Manual

Table of Contents

Advertisement

58
 Remove the o-rings from the motor and disconnect the electrical wires. Note that
some motor assemblies have spring contacts between the motor and
electrical wires.
 Check the wiring connectors and terminals for corrosion. Clean any corrosion off
with a small soft wire brush.
 Check the o-ring seals for signs of damage, wear or hardening. To ensure
chemical resistance replace the O-rings with Micron approved spares only.
Refitting of the motor is a reversal of the above procedure. Ensure all components
are clean before refitting.
When reconnecting the motor connect the, red, positive (+) wire to the terminal
marked with a small dot.
Ensure that the motor is clean and completely dry before refitting. Place the motor to
dry in a warm dry place or in direct sunlight. A small amount of moisture dispersing
lubricant may be applied to the motor to aid drying. Do not use solvent or silicone
sprays, heat or flame on the motor.
9.5

Flow Meter Replacement and Cleaning

The Flow meter is a push fit into the control unit housing.
 Remove the housing cover from the control unit (held by 2 self tapping screws).
 Remove the plastic elbows from the rear of the flow meter.
 Gently ease the flow meter from the front of the control unit housing.
Micron Sprayers Ltd. Spraydome/Undavina and Spraymiser
Maintenance
-
+