Options P1Da, P2Da - Electric Two-Position Control With Pcor - Danfoss H1 Series Technical Information

Bent axis motors
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
Options P1DA, P2DA – electric two-position control with PCOR
62 |
©
Danfoss | December 2016
P1 – electric two-position control 12V/de-energized = min. displacement with electric prop. PCOR
12V
P2 – electric two-position control 24V/de-energized = min. displacement with electric prop. PCOR
24V
DA – with electric proportional PCOR / without Brake Pressure Defeat
C
Caution
This control is not for use in propel applications.
L2
A
B
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
PCOR pressure (bar) versus Input command (mA)
350
300
250
200
150
100
50
0
0
200
400
Maximum PCOR setting = 300 bar [4351 psi], * Production test setting = 240 bar
C
Caution
If the signal to the PPCOR is lost or drops below the range shown in the chart, the PCOR setting will
potentially increase to pressure levels above the recommended application limits or the regulated
pressure control of the pump, and in effect, disable the PCOR function.
The PCOR pressure level can be proportionally changed with the input current to the solenoid.
MA
N
n
C6
min
max
M4
M5
MB
P003456
P2
P1
600
800
1000
Options P1DA, P2DA
L1
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
240*
1200
1400
1600
mA
P003 485
11037153 | BC00000043en-US1103