Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Operation

Loop flushing shuttle spool

20 |
©
Danfoss | December 2016
An integral loop flushing shuttle spool is used to separate system A and system B pressures.
System delta pressure will cause the shuttle spool to shift, allowing the low side system pressure to flow
to the loop flushing relief valve.
A
LFRV
Legend:
A
System loop A
B
System loop B
LFRV
to Loop flushing relief valve
W
Warning
Unintended vehicle or machine movement hazard.
Excessive motor loop flushing flow may result in the inability to build required system pressure in some
conditions. Maintain correct charge pressure under all conditions of operation to maintain pump control
performance in hydrostatic systems.
B
P006033
L2
A
B
P003 437