Options D1M1, D2M2 - Electric Proportional Control With Pcor And Electric Bpd - Danfoss H1 Series Technical Information

Bent axis motors
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
Options D1M1, D2M2 – electric proportional control with PCOR and electric BPD
46 |
©
Danfoss | December 2016
D1 – electric proportional 12 V / de-energized = max. displacement
M1 – with PCOR / with electric BPD 12 V / de-energized BPD = PCOR active at port B
D2 – electric proportional 24 V / de-energized = max. displacement
M2– with PCOR / with electric BPD 24 V / de-energized BPD = PCOR active at port B
Hydraulic schematic
MA
L2
A
C5
B
MB
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
Displacement (%) versus Input Command (mA)
100%
80%
60%
D2
40%
20%
0%
0
200
400
600
D1, D2 = D1, D2 Control
Z = Start setting range
Grey area = Intended to be used for zero degree capability.
For the formulas to calculate an input command dependent on displacement, please see
D2MA – electric proportional control with PCOR
N
n
max
min
C 1
L1
M4
M5
P301 326
D1
800
1000
1200
1400
1600
on page 44.
D1M1, D2M2 option
Solenoid C1
De-energized = max. displacement
Full-energized = min. displacement
PCOR
32°
160 bar
300 bar
[2321 psi]
[4351 psi]
Z
1800
mA
P301 328
Options D1MA,
11037153 | BC00000043en-US1103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 060H1b 080H1b 110H1b 160H1b 210H1b 250