Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
Options T1G1, T2G2 – electric two-position control with PCOR and electric BPD
60 |
©
Danfoss | December 2016
T1 – electric two-position 12 V / de-energized = min. displacement
G1 – with PCOR / with electric 12 V BPD, de-energized BPD = PCOR active at port B
T2 – electric two-position 24 V / de-energized = min. displacement
G2 – with PCOR / with electric 24 V BPD, de-energized BPD = PCOR active at port B
MA
L2
A
C6
C5
B
MB
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
Displacement versus control signal versus PCOR pressure
1
2
12 V/24 V
Solenoid Data C5 (BPD) and C6 (Two-Position Control)
Description
Min. supply voltage
Max. supply voltage (continuous)
Nominal coil resistance @ 20 °C [68 °F]
Recommended input current
N
n
max
min
L1
M4
M5
P006 067
PCOR
32°
160 bar
300 bar
[2321 psi]
[4351 psi]
3
P003 409
12 V
9.5 V
DC
14.6 V
DC
8.4 Ω
1050 mA
Options T1G1, T2G2
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
Where:
1
Maximum displacement
2
Minimum displacement
3
Start setting range
24 V
19 V
DC
29 V
DC
34.5 Ω
500 mA
11037153 | BC00000043en-US1103