Option Tada - Pressure Compensator Over Ride - Danfoss H1 Series Technical Information

Bent axis motors
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
Option TADA – Pressure Compensator Over Ride
©
Danfoss | December 2016
TA – Pressure Compensator Over Ride / default (high pressure below PCOR pressure = min.
displacement)
DA – with Pressure Compensator Over Ride / without Brake Pressure Defeat
C
Caution
This control is not for use in propel applications.
Hydraulic schematic
MA
L2
A
B
MB
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
1
2
Default: High pressure below PCOR pressure = min. displacement
N
n
max
min
L1
P301 327
M4
M5
PCOR
32°
160 bar
300 bar
[2321 psi]
[4351 psi]
3
P301 329
Option TADA
Hydraulic actuator X1
Non-pressurized = min. displacement.
Pressurized = max. displacement.
Where:
1
Max. displacement
2
Min. displacement
3
Start setting range
11037153 | BC00000043en-US1103 | 85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 060H1b 080H1b 110H1b 160H1b 210H1b 250

Table of Contents