Danfoss H1 Series Technical Information page 63

Bent axis motors
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
©
Danfoss | December 2016
Below are formulas to calculate pressure level dependent on input current:
Voltage
All sizes (mA)
12 V
I
= – 2.724 x P
PCOR
24 V
I
= – 1.399 x P
PCOR
Proportional solenoid data C6
Description
Maximum current
@ 20 °C [68 °F]
Nominal coil resistance
@ 80 °C [176 °F]
Inductance
Range
PWM
Frequency (preferred)
IEC 60 529
IP Rating
DIN 40 050, part 9
Connector color
*
PWM signal required for optimum control performance.
Variables:
+ 1453.8
P
= PCOR pressure level (bar)
PCOR
PCOR
I
= Current input to proportional PCOR solenoid (mA)
+ 735.7
PCOR
PCOR
12 V
1800 mA
3.66 Ω
4.52 Ω
33 mH
70-200 Hz
*
100 Hz
IP 67
IP 69K with mating connector
Black
24 V
920 mA
14.20 Ω
17.52 Ω
140 mH
11037153 | BC00000043en-US1103 | 63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 060H1b 080H1b 110H1b 160H1b 210H1b 250