H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Dimensions – Controls on H1B motors

Option LHBA (Hydraulic proportional control)

132 |
©
Danfoss | December 2016
1. Pilot Pressure Gauge Port "X1" ISO 11926-1 9/16-8
2. Start pressure adjustment screw
SAE mounting flange per ISO 3019/1 dimensions (mm [in])
Size 060
Size 080
SAE 127-4
SAE 127-4
272.3 [10.72]
289.9 [11.41]
AA
157.4 [6.20]
163.3 [6.43]
AB
242.6 [9.55]
260.3 [10.25]
EA
115.0 [4.53]
120.9 [4.76]
EB
DIN B4 HL mounting flange per ISO 3019/2 dimensions, (mm [in])
Size 060 – DIN 125 Size 080 – DIN 140 Size 110 – DIN 160 Size 160 – DIN 180 Size 210 – DIN 200
247.8 [9.76]
AA
157.4 [6.20]
AB
218.1 [8.59]
EA
115.0 [4.53]
EB
Size 250 is not available.
Cartridge mounting flange dimensions (mm [in])
Size 060
Cartridge 160
188.1 [7.41]
AA
157.4 [6.20]
AB
158.4 [6.24]
EA
115.0 [4.53]
EB
Size 210 and 250 are not available.
1
EA
AA
2
X
Size 110
SAE 152-4
316.4 [12.46]
167.7 [6.60]
286.8 [11.29]
138.4 [4.93]
265.9 [10.47]
283.9 [11.18]
163.3 [6.43]
167.7 [6.60]
236.3 [9.30]
254.3 [10.01]
120.9 [4.76]
125.3 [4.93]
Size 080
Cartridge 190
187.5 [7.38]
163.3 [6.43]
169.1 [6.66]
120.9 [4.76]
X
P108795
Size 160
Size 210
SAE 152-4
SAE 165-4
371.6 [14.63]
343.8 [13.53]
183.5 [7.22]
176.4 [6.94]
337.8 [13.3]
314.00 [12.36]
141.1 [5.56]
134.0 [5.28]
311.7 [12.27]
176.4 [6.94]
282.1 [11.11]
134.0 [5.28]
Size 110
Size 160
Cartridge 200
Cartridge 200
201.9 [7.95]
229.3 [9.03]
167.7 [6.60]
176.4 [6.94]
172.3 [6.78]
199.7 [7.86]
138.4 [4.93]
134.0 [5.28]
11037153 | BC00000043en-US1103
Size 250
SAE 165-4
390.3 [15.37]
189.6 [7.46]
357.4 [14.07]
147.3 [5.80]
339.6 [13.37]
183.5 [7.22]
306.7 [12.07]
141.1 [5.56]