Danfoss H1 Series Technical Information page 35

Bent axis motors
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Master Model Code
©
Danfoss | December 2016
A
Z
B
H1 B
A
A
Q – PCOR pressure setting
00
For all controls without PCOR function
16
160 bar [2321 psi]
17
170 bar [2466 psi]
18
180 bar [2611 psi]
19
190 bar [2756 psi]
20
200 bar [2901 psi]
21
210 bar [3046 psi]
22
220 bar [3191 psi]
*
Standard setting at production test for P* controls:
800 mA for P1
400 mA for P2
R – Paint and nametag
NNN
Black paint and Nametag
C
D E
F
G
H
23
*
24
25
26
27
28
29
30
J
K
L
M
N
N N
230 bar [3336 psi]
240 bar [3481 psi] – Standard setting
250 bar [3626 psi]
260 bar [3771 psi]
270 bar [3916 psi]
280 bar [4061 psi]
290 bar [4206 psi]
300 bar [4351 psi]
11037153 | BC00000043en-US1103 | 35
P
Q
R
N N N

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 060H1b 080H1b 110H1b 160H1b 210H1b 250

Table of Contents