C options: Motion control and relay card
Available for the full product range
Motion control and relay card
C
VLT® Motion Control MCO 305
VLT® Synchronizing Control MCO 350
VLT® Positioning Controller MCO 351
VLT® Extended Relay Card MCB 113
VLT® Extended Relay Card
MCB 113
The VLT® Extended Relay Card MCB 113 adds
inputs/outputs for increased flexibility.
7 digital inputs
2 analog outputs
4 SPDT relays
Meets NAMUR recommendations
Galvanic isolation capability
Ordering number
130B1164 standard
130B1264 coated (Class 3C3/IEC 60721-3-3)
VLT® Motion Control
MCO 305
An integrated programmable motion controller
adding extra functionality for VLT® Automation-
Drive FC 301 and FC 302.
VLT® Motion Control Option MCO 305 offers
easy-to-use motion functions combined with
programmability – an ideal solution for posi-
tioning and synchronizing applications.
Synchronization (electronic shaft),
positioning and electronic cam control
2 separate interfaces supporting both
incremental and absolute encoders
1 encoder output (virtual master function)
10 digital inputs
8 digital outputs
D option: 24 V back-up power supply
Available for the full product range
24 V back-up power supply
D
VLT® 24 V DC Supply Option MCB 107
VLT® 24 V DC Supply
MCB 107
Connect an external DC supply to keep the
control section and any installed option func-
tioning during power failure.
Support of CANopen motion bus, encoders
and I/O modules
Sends and receives data via fieldbus
interface (requires fieldbus option)
PC software tools for debugging and
commissioning: Program and Cam editor
Structured programming language with
both cyclic and event-driven execution
Ordering number
130B1134 standard
130B1234 coated (Class 3C3/IEC 60721-3-3)
VLT® Synchronizing
Controller MCO 350
The VLT® Synchronizing Controller MCO 350 for
VLT® AutomationDrive expands the functional
properties of the AC drive in synchronizing ap-
plications, and replaces traditional mechanical
solutions.
Speed synchronizing
Position (angle) synchronizing with or
without marker correction
On-line adjustable gear ratio
On-line adjustable position (angle) offset
Encoder output with virtual master function
for synchronization of multiple followers
Control via I/Os or fieldbus
Home function
Configuration as well as read-out of status
and data via the LCP
This enables full operation of the LCP (includ-
ing the parameter setting) and all installed
options without connection to mains.
Input voltage range ....................24 V DC +/- 15%
(max. 37 V for 10 sec.)
Max. input current .............................................. 2.2 A
Max. cable length ...............................................75 m
Input capacitance load ............................. < 10 uF
Power-up delay .................................................< 0.6 s
Typecode position
Ordering number
130B1152 standard
130B1252 coated (Class 3C3/IEC 60721-3-3)
VLT® Positioning Controller
MCO 351
The VLT® Positioning Controller MCO 351 offers
a host of user-friendly benefits for positioning
applications in many industries.
Features:
Relative positioning
Absolute positioning
Touch-probe positioning
End-limit handling (software and hardware)
Control via I/Os or fieldbus
Mechanical brake handling (programmable
hold delay)
Error handling
Jog speed/manual operation
Marker related positioning
Home function
Configuration as well as read-out of status
and data via the LCP
Ordering number
130B1153 standard
130B1253 coated (Class 3C3/IEC 60721-3-3)
Typecode position
Ordering number
130B1108 standard
130B1208 coated (Class 3C3/IEC 60721-3-3)
| Content | Danfoss Drives · DKDD.PB.302.A8.02
16
16 and 18
17
19
49