Customer ports
Size
060
1)
DN19 typ I
Axial and radial
2)
Case drain ports
2)
Axial gauge ports
0.875-14UN-2B
7
[
-14UN-2B]
8
2)
Gauge ports
1)
Split flange boss per ISO 6162, 40 MPa series.
2)
SAE O-ring boss
Output speed
Features
max.displ. 32°
Rated output
min. displ. 6°
speed
zero displ. 0°
max. displ. 32°
Maximum output
min. displ. 6°
speed
zero displ. 0°
System and case pressure, Ambient temperature
Parameter
Maximum working
Maximum
System pressure
Minimum above case pressure
(open and closed circuit)
Rated
Case pressure
Maximum
Minimum
Maximum
Ambient
*
temperature
Minimum
*
Air temperature close to the unit
080
110
DN25 typ I
DN25 typ I
0.875-14UN-2B
7
[
-14UN-2B]
8
1.0625-12UN-2B [1
0.5625-18UNF-2B [
Unit
060
080
3600
3200
5900
5300
6600
5950
-1
min
(rpm)
4500
4100
7250
6600
7950
7200
Unit
bar [psi]
°C [°F]
160
210
DN32 typ I
DN32 typ I
1.0625-12UN-2B
1.313-12UN-2B
1
[1
-12UN-2B]
[1
16
1
-12UN-2B]
16
9
-18UNF-2B]
16
Size
110
160
2900
2600
4800
4250
5350
4750
3700
3300
5950
5250
6500
5750
All sizes
450 [6527]
480 [6962]
See graphs in
Required inlet pressure diagrams
(for cylinder block filling)
on page 14.
3 [44]
5 [73]
0.3 [4]
70 [158]
-40 [-40]
11037153 | BC00000043en-US1103
250
DN32 typ I
5
-12UN-2B]
16
210
250
2350
2200
3850
3650
4300
4050
3000
2800
4800
4500
5250
4900