Danfoss H1 Series Technical Information page 105

Bent axis motors
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Dimensions
Axial and radial ports dimensions, mm [in]
Measure
Size 060
219.1 [8.63]
AA
114.7 [4.52]
AB
193.6 [7.62]
AC
112.7 [4.44]
AD
67.3 [2.65] max
AE
220.8 [8.69]
AF
180.6 [7.11]
BA
32.3 [1.27]
BB
74.4 [2.93]
BC
165.3 [6.51]
BD
83.8 [3.30]
BE
180.6 [7.11]
BH
32.3 [1.27]
BJ
69.5 [2.74]
BK
50.8 [2.0]
BL
23.8 [0.94]
BM
209.3 [8.24]
CA
40.6 [1.6]
CB
48.0 [1.89]
CC
50.8 [2.0]
CD
23.8 [0.94]
CE
45.0 [1.77]
CF
85.8 [3.38]
CG
18.0 [0.71]
CH
68.0 [2.68]
CJ
70.0 [2.76]
CK
58.9 [2.32]
CL
89.3 [3.52]
CM
209.6 [8.25]
CN
40.7 [1.60]
CO
48.0 [1.89]
CP
17°
α
©
Danfoss | December 2016
Size 080
237.4 [9.35]
119.4 [4.70]
206.6 [8.13]
112.7 [4.44]
67.3 [2.65] max
239.5 [9.43]
195.1 [7.68]
34.7 [1.38]
78.0 [3.07]
174.0 [6.85]
90.6 [3.54]
194.8 [7.67]
34.7 [1.37]
75.2 [2.96]
57.2 [2.25]
27.8 [1.09]
226.2 [8.91]
43.7 [1.72]
50.0 [1.97]
57.2 [2.25]
27.8 [1.09]
46.0 [1.81]
90.0 [3.54]
22.0 [0.87]
80.0 [3.15]
75.0 [2.95]
65.3 [2.57]
93.7 [3.69]
226.6 [8.92]
43.8 [1.72]
50.0 [1.97]
17°
For further detailed information about DIN ports dimensions see the
926-1
on page 106.
Legend:
1 Loop flushing relief valve
2 Loop flushing shuttle spool
3 Speed sensor
Size 110
Size 160
255.5 [10.06]
283.0 [11.14]
130.8 [5.15]
138.2 [5.44]
224.1 [8.82]
242.5 [9.55]
112.7 [4.44]
112.7 [4.44]
67.3 [2.65] max
67.3 [2.65] max
257.9 [10.15]
283.0 [11.14]
207.8 [8.18]
232.0 [9.13]
37.5 [1.48]
42.0 [1.65]
88.9 [3.50]
99.9 [3.93]
187.5 [7.38]
212.1 [8.35]
100.9 [3.97]
111.7 [4.40]
207.8 [8.18]
232.0 [9.13]
37.5 [1.48]
42.0 [1.65]
85.0 [3.35]
96.0 [3.78]
57.2 [2.25]
66.6 [2.62]
27.8 [1.09]
31.8 [1.25]
244.3 [9.62
267.0 [10.51]
48.0 [1.89]
52.1 [2.05]
50.0 [1.97]
60.0 [2.36]
57.2 [2.25]
66.6 [2.62]
27.8 [1.09]
31.8 [1.25]
63.0 [2.48]
54.5 [2.15]
96.0 [3.78]
102.2 [4.02]
21.0 [0.83]
23.0 [0.91]
87.0 [3.43]
90.9 [3.58]
83.0 [3.27]
96.5 [3.8]
68.8 [2.71]
75.8 [2.98]
97.2 [3.83]
105.6 [4.16]
245.3 [9.66]
267.9 [10.55]
48.2 [1.90]
52.3 [2.06]
50.0 [1.97]
60.0 [2.36]
19°
17°
4 Minimum angle stop adjustment
5 Connector: DT04-2P
6 Alternate position of case drain port
11037153 | BC00000043en-US1103 | 105
Size 210
308.9 [12.16]
145.5 [5.73]
257.7 [10.15]
112.7 [4.44]
67.3 [2.65] max
308.9 [12.16]
256.1 [10.08]
46.4 [1.83]
108.2 [4.26]
236 [9.29]
120.8 [4.76]
256.1 [10.08]
46.4 [1.83]
104.3 [4.11]
66.6 [2.62]
31.8 [1.25]
291.1 [11.46]
56.1 [2.21]
65 [2.56]
66.6 [2.62]
31.8 [1.25]
66.9 [2.63]
108.5 [4.27]
25 [0.98]
104.3 [4.11]
103.5 [4.07]
84.9 [3.34]
111.2 [4.38]
291.8 [11.49]
56.6 [2.23]
65 [2.56]
17°
DIN flange design ports per ISO 11

Hide quick links: