Status and Statistics
RMON
STEP 3
STEP 4
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
Enter the parameters.
•
Alarm Entry—Displays the alarm entry number.
•
Interface—Select the type of interface for which RMON statistics are displayed.
•
Counter Name—Select the MIB variable that indicates the type of occurrence
measured.
•
Sample Type—Select the sampling method to generate an alarm. The options are:
-
Absolute—If the threshold is crossed, an alarm is generated.
-
Delta—Subtracts the last sampled value from the current value. The difference in
the values is compared to the threshold. If the threshold was crossed, an alarm is
generated.
•
Rising Threshold—Enter the value that triggers the rising threshold alarm.
•
Rising Event—Select an event to be performed when a rising event is triggered. Events
are configured in the
•
Falling Threshold—Enter the value that triggers the falling threshold alarm.
•
Falling Event—Select an event to be performed when a falling event is triggered.
•
Startup Alarm—Select the first event from which to start generation of alarms. Rising
is defined by crossing the threshold from a low-value threshold to a higher-value
threshold.
-
Rising Alarm—A rising value triggers the rising threshold alarm.
-
Falling Alarm—A falling value triggers the falling threshold alarm.
-
Rising and Falling—Both rising and falling values trigger the alarm.
•
Interval—Enter the alarm interval time in seconds.
•
Owner—Enter the name of the user or network management system that receives the
alarm.
Click Apply. The RMON alarm is saved to the Running Configuration file.
RMON Events Control
page.
4