Electrical wiring

6.1 Electrical configuration - I/O module

Use wire gauge corresponding with the connection cable supplied!
Lay load lines separately to measuring lines!
A24/25
A24/25
A24/25
Mixing valve 3rd
(3rd mixed cycle)
Mixing valve 2nd
(2nd mixed cycle)
Mixing valve 1st
(1st mixed cycle)
A04
A04
A04
Pumpe 3 Kreis 230V
Pumpe 3 Kreis 230V
Pumpe 3 Kreis 230V
Pump 3 cycle 230V
(3rd mixed cycle)
Pumpe 2 Kreis 230V
Pumpe 2 Kreis 230V
Pumpe 2 Kreis 230V
Pump 2 cycle 230V
(2nd mixed cycle)
A02
A02
A02
Pumpe 1 Kreis 230V
Pumpe 1 Kreis 230V
Pumpe 1 Kreis 230V
Pump 1 cycle 230V
(1st mixed cycle)
Pumpe 230V
Pumpe 230V
Pumpe 230V
Pump 230V
(unmixed cycle)
Kühlen 230V
Cooling 230V
Kühlen 230V
Kühlen 230V
Changeover valve
Umschaltventil
Umschaltventil
Umschaltventil
Pump 230V
Pumpe 230V
Pumpe 230V
Pumpe 230V
Kühlen
Kühlen
Kühlen
Cooling
Nicht Belegt !
Not connected!
2nd Heat generator
Nicht Belegt !
Nicht Belegt !
Nicht Belegt !
A11
A11
A11
Pump (230V)
Pumpe ( 230 V )
Pumpe ( 230 V )
Pumpe ( 230 V )
Drinking water circulation
Trinkwasser Zirkulation
Trinkwasser Zirkulation
Trinkwasser Zirkulation
A10
A10
A10
Umschaltventil
Changeover valve
Umschaltventil
Umschaltventil
Trinkwasser 230V
Drinking water 230V
Trinkwasser 230V
Trinkwasser 230V
Secondary (230 V)
Sekundär ( 230 V )
Sekundär ( 230 V )
Sekundär ( 230 V )
Spannungsversorgung
Power supply
Spannungsversorgung
Spannungsversorgung
Sekundär ( 230 V )
Sekundär ( 230 V )
Sekundär ( 230 V )
Secondary (230 V)
Spannungsversorgung
Spannungsversorgung
Power supply
Spannungsversorgung
Power supply
Spannungsversorgung
Spannungsversorgung
Spannungsversorgung
I/O Modul ( 230 V )
I/O Modul ( 230 V )
I/O module (230 V)
I/O Modul ( 230 V )
We reserve the right to make technical changes, and provide no guarantee as to the accuracy of this data!
This hydraulic scheme is only for planning assistance and does not replace an assembly drawing!
Technische Änderungen vorbehalten. Angaben ohne Gewähr. / We reserve the right to make technical changes, and provide no guarantee as to the accuracy of this data!
Technische Änderungen vorbehalten. Angaben ohne Gewähr. / We reserve the right to make technical changes, and provide no guarantee as to the accuracy of this data!
Dieses Hydraulikschema dient lediglich als Planungshilfe und ersetzt keine Montagezeichnung! / This hydraulic scheme is only for planning assistance and does not replace an
Dieses Hydraulikschema dient lediglich als Planungshilfe und ersetzt keine Montagezeichnung! / This hydraulic scheme is only for planning assistance and does not replace an
assembly drawing!
assembly drawing!
64
Closed
Open
General alarm
Closed
Open
legionella function
2nd heat generator
Closed
Open
heating
Closed
Open
Reserve
Reserve
Reserve
Reserve
Nicht Belegt !
Nicht Belegt !
Reserve
Reserve
Reserve
230 V
HC 3rd mixed
Inlet sensor
HC 3rd mixed
Hygiene
HC 2nd mixed
Inlet sensor
HC 2nd mixed
HC 1st mixed
Pipe trace
Inlet sensor
HC 1st mixed
Reserve
HC unmixed
Inlet sensor
HC unmixed
Cooling
Heating
External probe
Drinking water probe
Circulation
Drinking water probe
Top
Drinking water probe
Bottom
SQW (reserve)
Inlet sensor
SQW (reserve)
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
ES contact
Reserve
RC Kodierwiderstand
RC Kodierwiderstand
RC Coding resistor
BUS 3 communication
Reserve!
BUS 2 communication
RCCB (Heat pump)
BUS 2 communication
Control element (terminal)
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
A 43 PWM/0-10V Pumpe
A 43 PWM/0-10V Pumpe
A 43 PWM/0-10V Pumpe
PWM/0-10V pump
3.gem.Kreis
3.gem.Kreis
3.gem.Kreis
3rd mix. cycle
A 42 PWM/0-10V Pumpe
A 42 PWM/0-10V Pumpe
A 42 PWM/0-10V Pumpe
PWM/0-10V pump
2.gem.Kreis
2.gem.Kreis
2.gem.Kreis
2nd mix. cycle
A 41 PWM/0-10V Pumpe
A 41 PWM/0-10V Pumpe
A 41 PWM/0-10V Pumpe
PWM/0-10V pump
1.gem.Kreis
1.gem.Kreis
1.gem.Kreis
1st mix. cycle
S0 PV Einspeisung
S0 PV Einspeisung
A 40 PWM/0-10V Pumpe
A 40 PWM/0-10V Pumpe
A 40 PWM/0-10V Pumpe
PWM/0-10V pump
(min. 500 Imp./kWh
(min. 500 Imp./kWh
ungem.Kreis
ungem.Kreis
ungem.Kreis
Unmix. cycle
S0 PV feed-in
S0 PV Ertrag
S0 PV Ertrag
(min. 500 Imp./kWh)
(min. 500 Imp./kWh
(min. 500 Imp./kWh
S0 PV yield
S 27 Volumenstrom Impuls
S 27 Volumenstrom Impuls
(min. 500 Imp./kWh)
Trinkwasser
Trinkwasser
S0 Haushaltszähler
S0 Haushaltszähler
S0 Haushaltszähler
Drinking water
(min. 500 Imp./kWh
(min. 500 Imp./kWh
S0 household meter
S0 WP Stromzähler
S0 WP
S0 WP Stromzähler
(min. 500 Imp./kWh)
(min. 500 Imp./kWh
(min. 500 Imp./kWh
S0 HP electricity meter
(min. 500 Imp./kWh)