REMKO Smart Control Touch Operating Manual page 22

For sqw heat pumps
Hide thumbs Also See for Smart Control Touch:
Table of Contents

Advertisement

REMKO Smart-Control Touch
For optimal configuration of the cooling curve
parameters, the cooling load calculation and/or
energy consumption must be taken into account.
Differences between the installed parameters and
the design of the actual building can cause the
heat pump to run inefficiently.
Setting cooling curve:
1. Base point
In the "Settings" level, select the circuit to be
changed and the parameter "Cooling curve set-
ting". Change the value with "+/-" under the cooling
curve schematic and select the next value with
"Next". Then confirm with "OK".
User level
Settings
e.g. unmixed circuit
Cooling curve adjustment
Setting the base point
22
Expert level
¯
¯
¯
¯
2. Standard inlet temperature
Change the value of the setting of the inlet temper-
ature and the outside temperature with "+/-" and
select the next value with "Next". Then confirm with
"OK".
User level
Settings
e.g. unmixed circuit
Cooling curve adjustment
Setting the standard inlet temperature
A cooling function via the cooling curve setting
is only enabled by REMKO if the corresponding
humidity probe is installed!
NOTICE!
At least one dew point monitor with corre-
sponding probes should be installed to protect
the system in the case of panel heating.
Expert level
¯
¯
¯
¯