REMKO Smart-Control Touch
Setting the heating curve:
1. Base point
In this level, select the circuit to be changed and
select the parameter "Heating curve settings".
Change the value with "+/-" under the heating
curve schematic and select the next value with
"Next". Then confirm with "OK".
User level
Settings
e.g. unmixed circuit
Heating curve adjustment
Setting the base point
2. Standard inlet temperature
The standard inlet temperature is set using the
same procedure.
User level
Settings
e.g. unmixed circuit
Heating curve adjustment
Setting the standard inlet temperature
20
Expert level
¯
¯
¯
¯
Expert level
¯
¯
¯
¯
3. Set the standard outside temperature
The standard outside temperature can be changed
in the user and expert level.
Here, it is possible to set the standard outside tem-
perature to the respective value for heating and
cooling mode.
The standard outside temperature is only changed
once here for each active heating circuit. After
changing this parameter, the value is automatically
accepted with all active heating circuits.
For optimal configuration of the heating curve
parameters, the heating load calculation and/or
energy consumption must be taken into account.
Differences between the installed parameters and
the design of the actual building can cause the
heat pump to run inefficiently.
Access this parameter as follows:
User level
Settings
Heating/cooling
Building adaptation
Standard outside temperature
Expert level
¯
¯
¯
¯