REMKO Smart Control Touch Operating Manual page 60

For sqw heat pumps
Hide thumbs Also See for Smart Control Touch:
Table of Contents

Advertisement

REMKO Smart-Control Touch
Setpoint increase
After activating the system separation it is possible to select a setpoint increase, in order to balance the heat
losses with a heat exchanger.
Menu item
Setpoint temperature
Separate cooling buffer
Setting the building time constant
The building time constant specifies the ability of the building to retain heat. The building time constant is
dependent upon the type of building (see table). The value is also dependent on individual temperature per-
ception, and so the information in the table should only be treated as a guide.
Recommended are:
Building
Heat retention ability
type
Light
Low heat retention ability, e.g. prefab/wood-frame houses
Medium
Moderate heat retention ability, e.g. house made from hollow blocks
Heavy
High heat retention ability, e.g. brick house
Very heavy
Very high heat retention ability, e.g. exterior and interior walls > 30 cm
Passive
Well-insulated, e.g. zero-energy housing
Menu item
Building time constant
60
Parameter
0 - 10
Active/inactive
Parameter
0 - 100 h
Factory setting
5.0 K
Inactive
Recom-
mended value
approx. 10 h
approx. 20 h
approx. 30 h
approx. 60 h
approx. 100 h
Factory setting
According to design! - 10 h

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smart Control Touch and is the answer not in the manual?

Table of Contents