Timeslot Set Of The First Ethernet Line; Channel Selection Of The First Ethernet Line; Auto-Negotiation Set Of The First Ethernet Line; Default Port Mode Of The First Ethernet Line - Raisecom RC3000 User Manual

Pcm multi-service
Hide thumbs Also See for RC3000:
Table of Contents

Advertisement

www.raisecom.com
A.19.1 Timeslot Set of the first Ethernet line
In Ethernet sub-card setting menu press number key 1 to configure the number of occupied channels:
The first row displays present configuration value and the second row is for your new configuration.
If you do not set occupied channel number in the second row and just press ENTER, the old
configuration will be reserved. If you set the occupied channel number (the entering must within the
range of 0-31) and press ENTER, the new configuration will be effective. BackSpace key is
available to modify.
The rule of configuring channels is the same as that of V35, please refer to the relative section of
V35 sub-card set.
A.19.2 Channel selection of the first Ethernet line
In Ethernet user board setting menu press number key 2 to select data channel:
In this status use → key to change the configured value: Main channel or Single channel; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
A.19.3 Auto-negotiation Set of the first Ethernet line
In Ethernet user card setting menu press number key 3:
In this status use → key to change the configured value; Press ENTER to confirm configuration,
press E key to finish configuration, and ESC to cancel configuration. The configuration items are
Enable and Disable.
A.19.4 Default port mode of the first Ethernet line
In Ethernet user card setting menu press number key 4 to set the default port mode:
In this status use → key to change the configured value: 10M Half duplex, 10M Full duplex, 100M
Half duplex and 100M Full duplex; Press ENTER to confirm configuration, press E key to finish
configuration, and ESC to cancel configuration.
Note: Default port mode refers to the mode when Ethernet electric interface is LINK DOWN, and
when Ethernet electric interface is LINK UP it is in auto-negotiation mode.
A.19.5 Timeslot Set of the second Ethernet line
In Ethernet sub-card setting menu press number key 1 to configure the number of occupied channels:
User Card Slot Number=8
Input Slot Number(0-31):
Data Channel Select of the first Ethernet line: Main Channel (Single channel)
Auto-negotiation of the first Ethernet line: Enable
Default Port Mode of the first Ethernet line: 100M Full Duplex