Reset Ethernet Port; Rs232, Rs422 And Rs485 Sub-Card Setting Menu; Channel Band Width Set; 10/100Baset Auto-Negotiation Ethernet Sub-Card Setting Menu - Raisecom RC3000 User Manual

Pcm multi-service
Hide thumbs Also See for RC3000:
Table of Contents

Advertisement

www.raisecom.com
In this status use → key to change the configured value: Full duplex or Half duplex; Press ENTER to
confirm configuration, press E key to finish configuration, and ESC to cancel configuration.
Note: Default port mode refers to the mode when Ethernet electric interface is LINK DOWN, and
when Ethernet electric interface is LINK UP it is in auto negotiation mode.
A.16.5 Reset Ethernet Port
In Ethernet user board setting menu press number key 5 to reset the Ethernet electric interface and
there will be the confirm prompt:
In this status press Y to reset the board and press N to cancel the operation. Other entering are
invalid.
A.17 RS232, RS422 and RS485 sub-card setting menu
This section will explain the commands of RS232, RS422 and RS485 sub-card menu.
A.17.1 Channel Band Width Set
In user card setting menu press number key 1to configure channel band width::
In this status use → key to change the configured value: 64Kbps, 128Kbps; Press ENTER to confirm
configuration, press E key to finish configuration, and ESC to cancel configuration.
Note: Bandwidth set of RS232, RS422 and RS485 has not been fully realized now, and this function
is reserved.
A.18 10/100BaseT auto-negotiation Ethernet sub-card Setting menu
A.18.1 Sub-Board Slot Number
In Ethernet sub-card setting menu press number key 1 to configure the number of occupied channels:
The first row displays present configuration value and the second row is for your new configuration.
If you do not set occupied channel number in the second row and just press ENTER, the old
configuration will be reserved. If you set the occupied channel number (the entering must within the
range of 0-31) and press ENTER, the new configuration will be effective. BackSpace key is
available to modify.
The rule of configuring channels is the same as that of V35, please refer to the relative section of
V35 sub-card set.
To run this command will reset Ethernet port.
Run this command (Y/N):
Channel Band Width:64Kbps
User Card Slot Number=8
Input Slot Number(0-31):
User Manual
82

Advertisement

Table of Contents
loading

Table of Contents