  • Page 1 RC832-30(-BL) User Manual...
  • Page 2 Raisecom Technology Co., Ltd shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 3 Tel: +86-10-82883305 Fax: +86-10-82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL: http://www.raisecom.com Feedback Comments and questions about how the RC832-30(-BL) device works are welcomed. Please review...
  • Page 4: Table Of Contents

    CONTENTS Release Notes------------------------------------------------------------------------------------------------- 6 General Safety Instructions ------------------------------------------------------------------------------ 7 Safety Symbols ---------------------------------------------------------------------------------------------------------------------7 Handling Energized Products ---------------------------------------------------------------------------------------------------7 General Safety Practices ------------------------------------------------------------------------------------------------------------------------ 7 Connection of AC Mains ------------------------------------------------------------------------------------------------------------------------- 8 Connection of DC Mains ------------------------------------------------------------------------------------------------------------------------- 8 Preventing Electrostatic Discharge Damage --------------------------------------------------------------------------------8 Chapter 1 Product Overview ------------------------------------------------------------------------- 1 1.1 Overview------------------------------------------------------------------------------------------------------------------------1 1.2 Function features -------------------------------------------------------------------------------------------------------------1...
  • Page 6: Release Notes

    Release Notes Date of Release Manual Version Revisions 20071122 200706 REV.A...
  • Page 7: General Safety Instructions

    General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
  • Page 8: Connection Of Ac Mains

    be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts.
  • Page 9: Chapter 1 Product Overview

    RC832-30(-BL) series PDH multiplexer realizes the transmission of 1 line of E1 service. It operates in chassis developed by Raisecom and is generally applied to central site networking. The device is SNMP manageable.
  • Page 10 Note: Among RC83X series devices with optical transceivers for dual-strand fiber, the devices with same optical transceivers can inter-connect with each other. For example, RC832-30-BL-S1 can be inter-connected with RC831-30-FV35-S1, RC832-30 -S1 and other RC83X series devices with S1 optical transceivers.
  • Page 11: Chapter 2 Technical Specifications

    User Manual Chapter 2 Technical Specifications 2.1 Technical specifications of the E1 interface Bit Rate: 2048Kbps±50ppm Coding: HDB3 Interface Type: BNC or RJ-45 Interface Impedance: 75Ω or 120Ω Physical characteristic: comply with ITU-T G.703 recommendations Transfer characteristic: comply with ITU-T G.823 recommendations Jitter tolerance: comply with ITU-T G.823 recommendations...
  • Page 12: Power Supply

    User Manual 2.3 Power supply Power consumption: < 3W 2.4 Operating environment Operating temperature: 0 ~ 60℃ Operating humidity: ≤ 90% (25℃) 2.5 Storing environment Storing temperature: -40 ~ 80℃ Storing humidity: 5% ~ 90%, no condensation 2.6 Outline and structure...
  • Page 13: Chapter 3 Device Appearance And Descripiton

    User Manual Chapter 3 Device Appearance and Descripiton 3.1 Device front panel Figure 3-1 The front panel of RC832-30 Figure 3-2 The front panel of RC832-30-BL 3.2 Indicator description Power supply indicator: PWR (Green): power supply working status indicator...
  • Page 14 1 pair of BNC connectors provides 1 line of 75Ω unbalanced E1 signal. OUT: E1 output IN: E1 input RC832-30-BL 1 E1 balanced interface: 1 RJ-45 interface provides 1 line of 120Ω balanced E1 signal. Pin 1 and 2 output; pin 4 and 5 input Pin 3, 6, 7, 8 are unused Note: Please be sure that the pin arrangement of the connector of the balanced cable is correct.
  • Page 15: Chapter 4 Device Settings

    User Manual Chapter 4 Device Settings 4.1 DIP switch description 4.1.1 The location of the DIP switches There are an 8-bit DIP switch SW1 and a 4-bit DIP switch SW2 on the back of the print circuit board. 4.1.2 DIP switch description...
  • Page 16 User Manual Optical E1 Side Interface E1 Side Tester Side Local Remote Set remote bidirectional loopback on the local PDH multiplexer Optical E1 Side Interface E1 Side Tester Side Local Remote Set local bidirectional loopback on the local PDH multiplexer Note: Please note that when configuring any loopback on the local PDH multiplexer, the status of all loopback setting bits of the DIP switch on the remote PDH multiplexer must be OFF (no loopback).
  • Page 17: Default Settings

    User Manual DIP switch SW2 The DIP switch SW2 identifies the optical transceiver type adopted by the device. The settings of SW2 are completed by the manufacturer. Please keep the factory settings of SW2. They are not allowed to be changed.
  • Page 18: Chapter 5 Typical Application

    Client Site RLOS Device As is shown in the figure above, RC832-30 can be applied in pair and network management can be realized on the application. In addition, RC832-30 can also be inter-connected with RCMS2802-30FE/60FE-BL, RC832-60, RC832-30/60-BL, RC831-60-FV35, and etc.
  • Page 19 User Manual As is shown in the figure above, RC832-30-BL can be applied in pair and network management can be realized on the application. In addition, RC832-30-BL can also be inter-connected with RCMS2802-30FE/60FE-BL, RC832-30/60, RC832-60-BL, RC831-60-FV35, and etc.
  • Page 20: Chapter 6 Network Management Features

    Through Raisecom’s network management platform NView NNM V5.0 together with corresponding EMS RC002_5.0 (Build 3) or above version, users can view the status information of the RC832-30(-BL) device. Users can also control and configure the device on the network management platform.
  • Page 21: Chapter 7 Device Installation Preparation And Connection

    7.1.1 Make sure that the E1 cable applied meet the requirement of the device For RC832-30, coaxial cable of SYV75-5, SYV75-3 and SYV75-2-2 can be used as E1 cable. The E1 interfaces of RC832-30 are 75Ω unbalanced E1 interfaces. Please check the type, pin definition and impedance of the E1 interface of the device on the opposite site of the communication before connection.
  • Page 22: Installation Procedures

    User Manual 7.2 Installation procedures 7.2.1 Device installation Please fix the chassis on to the rack and insert the device into the slot of the chassis. Please fasten all screws. If network management will not be used, please make sure that the DIP switches on the module have been set according to need before being fixed into the chassis.
  • Page 23: Appendix A Faq

    User Manual Appendix A FAQ For some problems you may meet during installation and operation, please try to solve them following the suggestions below. For the problems can not be solved using the following suggestions, please contact with distributors for technical support.
  • Page 24 Address: 2 Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing Postcode: 100085 Tel: +86-10-82883305 Fax: +86-10-82883056 Email: export@raisecom.com http://www.raisecom.com...