1. Cut a 10" x 10" square hole in the wall adjacent to wall stud.
2. Install back box using 3 - #10 screws. Wood screws for wood studs and metal screws for metal studs.
3. Punch through knockouts and run cables as required.
4. After all electrical connections are made, place front panel against back box and fasten with supplied
security screws.
Connecting the Postal Lock Switch
The common connection (black wire) is connected to one terminal of the postal lock terminal connector.
For a standard postal lock the NC connection (white wire) is connected to the other terminal of the postal lock
terminal connector.
The standard postal lock is configured so that the bolt is retracted when the lock is engaged. (Key turned in
lock). Ensure the postal lock is mounted so that the switch lever moves when the postal lock is engaged.
Do not connect the postal lock switch until the postal lock is installed.