c. Select the Misc tab. The miscellaneous tables will be displayed.
d. In the Facility Code table select (double click) the Facility Code entry you wish to edit.
e. Enter the Facility Code and then press "Enter"
Note: Adding a Facility code is done by replacing one of the "0" entries with the Facility Code you wish to add.
Zero is not a valid facility code
f.
When all the entries have been competed, select the Save button.
g. To close the Form select the Close button.
h. Save and Upload the changed information.

19. Setup the Access Control Information

A. Default Settings
To assist you in configuring the CV-TAC400, the factory default file is set up with some useful default
settings.
Time Group 1 is set to allow access 24 hours per day 7 days per week holidays included.
Access Group 1 is doors number 1 though 8.
Access Level 1 is the combination of Time Group 1 and Access Group 1.
File: CV-TAC400_IN_MAN__NF_REV6.doc
Revised: September 2, 2014
Part No: 40-82B113
CV-TAC400 Installation Guide | 112