Value Range
Default Value
Web User Interface Reference
CFG_RTRY_INTVL
Value Format
Description
Value Range
Default Value
CFG_RESYNC_FROM_SIP
Value Format
Description
Value Range
Default Value
Web User Interface Reference
CFG_RESYNC_ACTION
Value Format
Description
Value Range
Default Value
CFG_FILE_KEY2
Value Format
Document Version: 2020-04
00:00–23:59
Note
•
If the value for this setting is any valid value other than an
empty string, the unit downloads the configuration files at the
fixed time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are disabled.
•
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Empty string
Time Resync
INTEGER
Specifies the period of time, in minutes, that the unit will retry
checking for an update of the configuration files after a configuration
file access error has occurred.
1–1440
30
STRING
Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Max. 15 characters
check-sync
Header Value for Resync Event
INTEGER
Specifies the value of the action after received resync NOTIFY.
•
0: Provisioning
•
1: TR-069 Inform
•
2: Reboot
0
STRING
4.8 Provisioning Settings
Administrator Guide