n
INSTRUCTION MANUAL
Photoelectric Sensor
FX-301 Series
Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.
• Never use this product as a sensing device for personnel protection.
• In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
For further details on the fiber sensor amplifier, please refer to our
Web site: www.panasonic-electric-works.com, or contact our office.
1
CAUTIONS
This product has been developed / produced for industrial use only.
Make sure to carry out wiring with the power OFF.
Verify that the supply voltage including the ripple is within the rating.
Do not connect the sensor to voltage that exceeds the rated range or
directly to an AC power supply: it may damage or burn the sensor.
Incorrect wiring or short-circuiting the load may damage or burn the
sensor.
When the emitting level function is turned from OFF to ON for any level,
the output may be unstable. Do not use the output control for at least
0.5s after starting emission. (See "PRO1" on page 6.)
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Do not use during the initial transient time (0.5s) after the power supply is
switched on.
This sensor is suitable for indoor use only.
You can extend the cable up to 100m max. with 0.3mm
5 to 8 units are connected in cascade, the limit is 50m; for 9 to 16 units in
cascade, 20m. However, in order to reduce noise, make the wiring as
short as possible.
Note that extending the cable increases the residual voltage.
Be sure to use the optional quick-connection cable when connecting to
the connector type sensor FX-301(P).
Avoid dust, dirt and steam.
Take care that the sensor does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkaline.
Do not use this sensor in an environment containing inflammable or
explosive gases.
Never disassemble or modify the sensor.
1
The digital fiber sensor FX-301(P) has been modified since production in June,
2004. Hence, this instruction manual has been changed to reflect the modifica-
tions.
Digital Fiber Sensor
MEUML-FX301 V1.1
1
WARNING
2
or more cable. If
2
PART DESCRIPTION
Q
W
E
R
T
Y U
RUN
TEACH
ADJ
No.
Part
Q
Operation indicator
(orange)
W
Stability indicator
(green)
E
RUN mode indica-
tor (green)
R
TEACH mode indi-
cator (yellow)
T
ADJ mode indicator
(yellow)
Y
Digital display (red)
U
L/D mode indicator
(yellow)
I
TIMER mode indica-
tor (yellow)
O
PRO mode indica-
tor (yellow)
P
Jog switch
{
Mode key
3
MOUNTING
You may break the spring hook if you do not follow the mounting
instructions carefully.
How to mount the amplifier
1 Fit the spring hook on a 35mm DIN rail and
push forward.
2 Slip the front part of the mounting section over
the DIN rail and release.
How to remove the amplifier
1 Push the amplifier forward
2 Lift up the front part of the amplifier.
1
I
O
P
{
PUSH
MODE
TIMER
CANCEL
Description
Lit when output is on.
Lit when detection is stable according
to the parameters set.
Lit when FX-301 is in RUN mode.
Lit when FX-301 is in TEACH mode.
Lit when FX-301 is in ADJ (threshold
value adjustment) mode.
Displays incident light intensity under
normal circumstances. Also displays
sub-modes and settings.
Lit when FX-301 is in L/D mode (Light-
ON, Dark-ON) mode.
Lit when FX-301 is in TIMER mode.
Lit when FX-301 is in PRO mode.
The jog switch allows you to select the
various sub-modes and confirm set-
tings.
The mode key allows you to switch
from mode to mode, or to cancel set-
tings and return to RUN mode.
35mm
1
2

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FX-301 Series

  • Page 1 TIMER MEUML-FX301 V1.1 CANCEL Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
  • Page 2: Connecting The Fiber Cable

    CONNECTING THE FIBER CABLE CASCADING  Make sure that the power supply is off while adding or removing  Be sure to fit the attachment to the fibers before inserting the amplifiers. fibers into the amplifier. For details, refer to the instruction manual ...
  • Page 3: Operation Procedure

     Press the jog switch to confirm settings. I/O CIRCUIT DIAGRAMS  Turn the jog switch to navigate between sub-modes. Terminal arrangement diagram, FX-301 connector type  When the jog switch is turned in RUN mode, the current threshold value is displayed.
  • Page 4: Teaching Mode

    If the jog switch is turned to the "+" side, the threshold level is shifted to a TEACHING MODE value approx. 15% higher than that set when the jog switch was pressed, yielding lower sensitivity. Use this method for reflective type fibers. If the jog switch is turned to the "-"...
  • Page 5 For an even more detailed explanation of PRO mode, check out our Web You can make fine adjustments to the threshold value while in ADJ mode. site for the “PRO Mode Operation Guide”, www.panasonic-electric- works.com, or contact our office. Step Description Press <MODE>...
  • Page 6 4 Press the jog switch to confirm settings. Mode Setting Description 5 Press <MODE> briefly at any time to move up one level. Press <MODE> for 2s to return to RUN mode. Level 4. Highest emitting power. PRO1 Level 3. Mode Setting Description...
  • Page 7 PRO3 Mode Setting Description PRO3 mode can load configuration settings from the data bank, i.e. “channel”, and save configuration settings to the data bank. Back-up ON. Mode Setting Description Back-up OFF. Prevents frequent overwriting of data in the Press the jog switch to load configuration EEPROM: the threshold values are not settings from the respective channel (1, 2 or stored in the EEPROM when teaching via...
  • Page 8: Error Indication

    KEY LOCK FUNCTION The key lock function prevents settings from being changed inadvertently. While in RUN mode, press <MODE> + the jog switch for at least 2s to set or release the key lock function. When the keys are locked, only the threshold value confirmation and adjust functions are valid.
  • Page 9 Sub cable (1-core): CN-71-C1 (cable length 1m), CN-71-C2 (cable length 2m), CN-71-C5 (cable length 5m) URL : http://panasonic-electric-works.net/sunx Overseas Sales Division (Head Office) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 Europe Headquarter: Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany Phone: +49-8024-648-0...

This manual is also suitable for:

Fx-301pFx-301-c1Fx-301p-c1

Table of Contents