7.5 Operation at Over limit Input

P point control operation is as follows when Over limit input (+) or Over limit input (-) is ON.
Condition
When P point
control is turned ON.
During P point
control operation
Direction
Limit status
Over limit input (+):ON
Forward
Over limit input (-):ON
Over limit input (+):ON
Reverse
Over limit input (-):ON
Forward
Over limit input (+):ON
Reverse
Over limit input (-):ON
P Point Control: Multi - Stage Acceleration / Deceleration
Operation
Table not to move,
Limit error occurs.
Table not to move,
Limit error occurs.
Table not to move,
Limit error occurs.
Table not to move,
Limit error occurs.
Table stops,
Limit error occurs.
Table stops,
Limit error occurs.