Displaying the operational status of power
modules
Use the display power command to display the operational status of power modules.
<Sysname> display power
Power 0
Power 1
Table 8 Output description
Field
Power
Status
Displaying the temperature information of the
firewall
Use the display environment command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor
pperLimit
inflow 1
Table 9 Output description
Field
Sensor
Temperature
LowerLimit
Warning-UpperLimit
Alarm-UpperLimit
Shutdown-Upperlimit
Status: Normal
Status: Absent
Temperature LowerLimit Warning-UpperLimit
26
-5
Description
Temperature sensor:
•
•
•
Current temperature.
Low temperature alarm threshold.
Warning-level high temperature alarm threshold.
Alarm-level high temperature alarm threshold.
Shutdown-level high temperature alarm threshold. The firewall automatically
powers off when the temperature exceeds this threshold.
Description
Number of the power module.
Power module state:
•
Normal—The power module is operating correctly.
•
Absent—The power module is not in position.
•
Abnormal—The power module has failed.
48
inflow—Air inlet vent temperature sensor.
outflow—Air outlet vent temperature sensor.
hotspot—Hotspot temperature sensor.
35
Alarm-UpperLimit Shutdown-U
56
NA