The Operator Panel - Canon imagePRESS C800 Series Technical & Service Manual

Prismasync v4.1
Hide thumbs Also See for imagePRESS C800 Series:
Table of Contents

Advertisement

The operator panel

The operator panel
Introduction
This topic describes the main components of the operator panel.
NOTE
You can clean the screen of the operator panel with a 50% mix of water and isopropyl alcohol.
Use a lint-free cloth. Always put the cleaner onto the cloth and not directly on the screen.
Components of the operator panel
1. Sleep button (Moon button)
Depending on whether the host machine is currently active or in the sleep mode
• Put the machine in to sleep mode, or
• Wake up the machine from the sleep mode
• shut down the host machine and the controller
• Startup the controller after a shutdown
2. Stop button
Stop the host machine
• After a set, or
• As soon as possible
3. Paper tray button
Get direct access to the tray section on the operator panel to do the following:
• Check the content of all paper trays.
• Load a new media type into a paper tray.
• Change the media type which is available in one of the paper trays.
• Create a trace log on a USB stick. If an 11504 error is displayed, insert a USB stick and
press this key to create a trace log on the stick.
4. USB port
Used for:
• Connect spectrophotometer for calibration
• USB-stick for software installation
• USB-stick for backup/Restore
32
Chapter 4 - Using the PRISMAsync

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents