11 Drive Control, Duty Modes, and Programming
No.
(Hex.)
b1-03
Stopping Method Selection
(0182)
b1-04
Reverse Operation Selection
(0183)
C1-01
Acceleration Time 1
(0200)
RUN
C1-02
Deceleration Time 1
(0201)
RUN
C2-01
S-Curve Time @ Start of Accel
(020B)
C2-02
S-Curve Time @ End of Accel
(020C)
C2-03
S-Curve Time @ Start of Decel
(020D)
C2-04
S-Curve Time @ End of Decel
(020E)
C6-01
Normal / Heavy Duty Selection
(0223)
C6-02
Carrier Frequency Selection
(0224)
d1-01 to d1-16
Reference 1 to 16
(0280 - 0291)
RUN
d1-17
Jog Reference
(0292)
RUN
d2-01
Frequency Reference Upper Limit
(0289)
d2-02
Frequency Reference Lower Limit
(028A)
E1-01
Input AC Supply Voltage
(0300)
E1-04
Maximum Output Frequency
(0303)
E1-05
Maximum Output Voltage
(0304)
50
Name
V/f
CL-V/f
Sets the method to stop the motor after removing a Run command or entering a Stop command.
0 : Ramp to Stop
1 : Coast to Stop
2 : DC Injection Braking to Stop
3 : Coast to Stop with Timer
V/f
CL-V/f
Sets the reverse operation function. Disable reverse operation in fan or pump applications where reverse rotation is
dangerous.
0 : Reverse Enabled
1 : Reverse Disabled
V/f
CL-V/f
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
CL-V/f
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
CL-V/f
Sets the S-curve acceleration time at start.
V/f
CL-V/f
Sets the S-curve acceleration time at completion.
V/f
CL-V/f
Sets the S-curve deceleration time at start.
V/f
CL-V/f
Sets the S-curve deceleration time at completion.
V/f
CL-V/f
Sets the drive duty rating.
0 : Heavy Duty Rating
1 : Normal Duty Rating
V/f
CL-V/f
Sets the carrier frequency for the transistors in the drive.
1 : 2.0 kHz
2 : 5.0 kHz
3 : 8.0 kHz
4 : 10.0 kHz
5 : 12.5 kHz
6 : 15.0 kHz
7 : Swing PWM1 (Audible Sound 1)
8 : Swing PWM2 (Audible Sound 2)
9 : Swing PWM3 (Audible Sound 3)
A : Swing PWM4 (Audible Sound 4)
F : User Defined (C6-03 to C6-05)
V/f
CL-V/f
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
CL-V/f
Sets the Jog frequency reference in the units from o1-03 [Frequency Display Unit Selection]. Set H1-xx = 6 [MFDI
Function Select = Jog Reference Selection] to use the Jog frequency reference.
V/f
CL-V/f
Sets maximum limit for all frequency references. The maximum output frequency is 100%.
V/f
CL-V/f
Sets minimum limit for all frequency references. The maximum output frequency is 100%.
V/f
CL-V/f
Sets the drive input voltage.
V/f
CL-V/f
Sets the maximum output frequency for the V/f pattern.
V/f
CL-V/f
Sets the maximum output voltage for the V/f pattern.
Description
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV