5 Common Drive Specifications
Item
Stops when power loss is longer than 15 ms.
Continues operation if power loss is shorter than 2 s (depending on parameter settings).
Momentary Power
Note:
Loss Ride-thru
• Stop time may be shortened depending on the load and motor speed.
• Drive capacity will change the continuous operation time.
Heatsink Overheat
Thermistor
Protection
Braking Resistor
Overheat detection for braking resistor (optional ERF-type, 3% ED)
Overheat Protection
Stall Prevention
Stall prevention is available during acceleration, deceleration, and during run.
Electronic circuit protection
Note:
Ground Fault
This protection detects ground faults during run. The drive will not provide protection when:
Protection
• There is a low-resistance ground fault for the motor cable or terminal block
• Energizing the drive when there is a ground fault.
DC Bus Charge LED Charge LED illuminates when DC bus voltage is more than 50 V.
Built-in to models 5382 to 5472
DC Link Choke
Item
Indoors
Area of Use
Overvoltage Category III
Permitted Frequency Fluctuation: ±5%
Power Supply
Permitted Voltage Fluctuation: -15% to +10%
• Three-phase AC power supply 500 V to 600 V at 50/60 Hz
• DC power supply 675 V to 848 V
IP20/UL Open Type/Heatsink External Mounting: -10 °C to +50 °C (14 °F to 122 °F)
IP55/UL Type 12 Heatsink External Mounting; front side: -10 °C to +50 °C (14 °F to 122 °F)
IP55/UL Type 12 Heatsink External Mounting; back side: -10 °C to +40 °C (14 °F to 104 °F)
Ambient Temperature
Setting
• When installing the drive in an enclosure, use a cooling fan or air conditioner to keep the internal air temperature in the permitted range.
• Do not let the drive freeze.
• You can use IP20/UL Open Type drives at a maximum of 60 °C (140 °F) when you derate the output current.
95% RH or less
Humidity
Do not let condensation form on the drive.
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Pollution degree 2 or less
Install the drive in an area without:
• Oil mist, corrosive or flammable gas, or dust
• Metal powder, oil, water, or other unwanted materials
Surrounding Area
• Radioactive materials or flammable materials, including wood
• Harmful gas or fluids
• Salt
• Direct sunlight
1000 m (3281 ft) maximum
Altitude
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
• 10 Hz to 20 Hz: 1 G (9.8 m/s
Vibration
• 20 Hz to 55 Hz:
5382 to 5472: 0.2 G (2.0 m/s
Installation
Install the drive vertically for sufficient airflow to cool the drive.
Orientation