YASKAWA GA800 600 V Drive Installation & Primary Operation page 52

For industrial applications
Table of Contents

Advertisement

11 Drive Control, Duty Modes, and Programming
No.
(Hex.)
H3-12
Terminal A2 Bias Setting
(041A)
RUN
H3-13
Analog Input FilterTime Constant
(041B)
H3-14
Analog Input Terminal Enable Sel
(041C)
H4-01
Terminal FM Analog Output Select
(041D)
H4-02
Terminal FM Analog Output Gain
(041E)
RUN
H4-03
Terminal FM Analog Output Bias
(041F)
RUN
H4-04
Terminal AM Analog Output
Select
(0420)
H4-05
Terminal AM Analog Output Gain
(0421)
RUN
H4-06
Terminal AM Analog Output Bias
(0422)
RUN
H4-07
Terminal FM Signal Level Select
(0423)
H4-08
Terminal AM Signal Level Select
(0424)
L1-01
Motor Overload (oL1) Protection
(0480)
L1-02
Motor Overload Protection Time
(0481)
52
Name
V/f
CL-V/f
Sets the bias of the analog signal input to MFAI terminal A2.
V/f
CL-V/f
Sets the time constant for primary delay filters on MFAI terminals.
V/f
CL-V/f
Sets the enabled terminal or terminals when H1-xx = C [MFDI Function Select = Analog Terminal Enable Selection] is
ON.
1 : Terminal A1 only
2 : Terminal A2 only
3 : Terminals A1 and A2
4 : Terminal A3 only
5 : Terminals A1 and A3
6 : Terminals A2 and A3
7 : Terminals A1, A2, and A3
V/f
CL-V/f
Sets the monitor number to send from MFAO terminal FM.
V/f
CL-V/f
Sets the gain of the monitor signal that is sent from MFAO terminal FM.
V/f
CL-V/f
Sets the bias of the monitor signal that is sent from MFAO terminal FM.
V/f
CL-V/f
Sets the monitoring number to be output from the MFAO terminal AM.
V/f
CL-V/f
Sets the gain of the monitor signal that is sent from MFAO terminal AM.
V/f
CL-V/f
Sets the bias of the monitor signal that is sent from MFAO terminal AM.
V/f
CL-V/f
Sets the MFAO terminal FM output signal level.
0 : 0 to 10 Vdc
1 : -10 to +10 Vdc
2 : 4 to 20 mA
V/f
CL-V/f
Sets the MFAO terminal AM output signal level.
0 : 0 to 10 Vdc
1 : -10 to +10 Vdc
2 : 4 to 20 mA
V/f
CL-V/f
Sets the motor overload protection with electronic thermal protectors.
0 : Disabled
1 : Variable Torque
2 : Constant Torque 10:1 Speed Range
3 : Constant Torque 100:1 SpeedRange
6 : Variable Torque (50Hz)
V/f
CL-V/f
Sets the operation time for the electronic thermal protector of the drive to prevent damage to the motor. Usually it is not
necessary to change this setting.
Description
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
OLV
CLV
AOLV
YASKAWA TOEPC7106170VA GA800 600 V Drive Installation & Primary Operation