ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-558
Page 3 of 3
NETWORK PARAMETER
PVC Logical Channel # *
Modulo
Packet Size *
Window Size *
M bit Support
Q bit Support (not supported)
D bit Support *
Keyboard Time-Out
SVC Craft Address
SVC TL1 Address
* These are user programmable parameters through the Craft Interface.
======================================================
Address Field Assignment: DTE
Figure 558-1. X.25 Port Configuration (with Default Settings)
2-188
© 2000, ADC Telecommunications, Inc.
Table 558-3. Network Layer X.25 Packet Parameters
SET
VALUE
8
Yes
X.25 CONFIGURATION
Data Link (LAPB) Parameters
Window Size: 7
Frame Size: 2104 bits
Network Layer Parameters
========================================
Virtual Circuit -
1
======
Circuit Type: PVC
Logical Channel: 1
Application: TL1
Packet Size: 128
Window Size: 2
D-bit Support: YES
Keyboard Timeout: N/A
SVC Craft Address:
SVC TL1 Address:
Press CONTROL-A For Assistance
RANGE
1 - 255
128, 256 octets
1 - 7
No, Yes
N/A for TL1; 0 minute,
1 minute, 5 minute,
10 minute, 15 minute,
30 minute, 45 minute, 1 hour
Up to 15 contiguous
digits, each 0 to 9 or blank
Up to 15 contiguous digits,
each 0 to 9 or blank
N2: 7
T1: 3
seconds
2
3
======
======
PVC
SVC
2
N/A
CRAFT
N/A
128
128
2
2
YES
YES
30 MIN
30 MIN
CONFIGURABLE
DEFAULT
See
Table 558-2
128
2
Yes
30 minute
(blank)
(blank)
6148-D
Need help?
Do you have a question about the Soneplex Broadband System and is the answer not in the manual?