ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-533
Page 2 of 5
Unit Equip State
Unit Service State: OOS
T1 Provision
T1 Service State
Line Code
Framing Format
Network DS1 Source: NRZ
BER Threshold
Span Power Setting: ENABLED
DS0 Channel
(B = blocked)
Unit Switch Settings:
Figure 533-1. RLX Configuration Screen (Broadband Chassis)
Note: The Unit Service State field default is UNEQUIPPED and the T1 Provision field
default is NO. When the Unit Service State field is set to EQUIPPED and the T1
Provision field is set to YES, this screen shows all other field defaults, as above.
FIELD
TYPE
Group
Toggle
Slot
Toggle
Circuit Identifier
Input
Unit Equip State
Toggle
*Note: The RLXIOR configuration field default values shown in this manual are valid for a system with an MPU installed.
2-110
© 2000, ADC Telecommunications, Inc.
RLX CONFIGURATION
Group: 1
Slot: 1
Circuit ID:
: EQUIPPED
Pulse Equalization
LBO Setting
: YES
Programmable Loopback
: OOS
NID Loopback
: AMI
Loopback Activation Code : 1101001111010011
: AUTO
Loopback Deactivate Code : 1001001110010011
Lpbk Timeout Disable Code: 1101010111010110
: 1E-7
Loopback Timeout Period
Network Keep Alive
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
. . . . . . . . .
.
.
Pulse Equalization: NOT APPL
NID: DISABLED
Press CONTROL-A For Assistance
Table 533-1. RLXIOR Configuration Fields
OPTIONS
1, 2, 3, 4, 5, 6, or 7
Specifies the module's group number
(groups 6 and 7 are not
designated on the chassis.
available in the 19-inch
LEC chassis)
1, 2, 3, or 4
Specifies the module's slot number in the
group designated on the chassis.
Enter up to 20 characters
This represents the customer's circuit ID.
The first and last characters must be alpha or
numeric; middle characters can be alpha,
numeric, or hyphens.
Equipped
Establishes communication with the MPU.
Module must be set to EQUIPPED before
remaining selections are allowed.
Unequipped
No communication with the MPU.
: NOT APPL
: UNIT SWITCH
: DISABLED
: ENABLED
: 0
: AIS
.
.
.
.
.
.
.
.
.
Span Power: DISABLED
LBO: 7.5
DESCRIPTION
minutes
.
.
.
.
dB
11783-A
DEFAULT*
1
1
Blank
UNEQUIPPED
(continued)