18. If you made changes to port configurations, log off and then log back on to the system to
implement the changes.
DLP-564
Reference:
DLP-526
Reference:
Stop! You have completed this procedure.
Port Label
Application
Baud Rate
Parity
Data Bits
Stop Bits
Flow Control
Keyboard Timeout:
TBOS Mode
Display 1 Response Address: NOT APPL
Display 2 Response Address: NOT APPL
COMMUNICATION
PARAMETER
Application
Baud Rate
Parity
Data Bits
Stop Bits
Flow Control
Keyboard Timeout
Note: For X.25 Port configuration, see DLP-558.
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
Craft Interface System Logoff
Craft Interface System Logon
SERIAL PORT CONFIGURATION
CRAFT
========
:
CRAFT
:
9600
:
NONE
:
8
:
1
:
NONE
30 MIN
TBOS CONFIGURATION
: EXPANDED
Press CONTROL-A For Assistance
Figure 549-1. Serial Port Configuration Screen
Table 549-1. Serial Port Default Settings
CRAFT PORT
(DCE)
CRAFT
9600
NONE
8
1
NONE
30 MIN
PORT 1/2
PORT 3
========
========
TBOS
X.25
2400
NOT APPL
ODD
NOT APPL
8
NOT APPL
2
NOT APPL
NONE
NOT APPL
NOT APPL
NOT APPL
PORT 1/2
PORT 3
(DTE)
(DTE)
TBOS
X.25
2400
Not Applicable
ODD
Not Applicable
8
Not Applicable
2
Not Applicable
NONE
Not Applicable
NOT APPL
Not Applicable