Unit Equip State
Unit Service State: OOS
T1 Provision
T1 Service State
Line Code
Framing Format
Network DS1 Source: NRZ
BER Threshold
Span Power Setting: UNIT SWITCH
DS0 Channel
(B = blocked)
Unit Switch Settings:
FIELD
TYPE
Group
Toggle
Slot
Toggle
Circuit Identifier
Input
Unit Equip State
Toggle
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
RLX CONFIGURATION
Group: 1
Slot: 1
Circuit ID:
: EQUIPPED
Pulse Equalization
LBO Setting
: YES
Programmable Loopback
: OOS
NID Loopback
: AUTO
Loopback Activation Code : 1101001111010011
: AUTO
Loopback Deactivate Code : 1001001110010011
Lpbk Timeout Disable Code: 1101010111010110
: 1E-7
Loopback Timeout Period
Network Keep Alive
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
. . . . . . . . .
.
.
Pulse Equalization: NOT APPL
NID: DISABLED
Press CONTROL-A For Assistance
Figure 534-1. RLX Configuration Screen
Table 534-1. RLX Configuration Fields
OPTIONS
1, 2, 3, 4, 5, 6, or 7
Specifies the module's group number
(groups 6 and 7 are not
designated on the chassis.
available in the 19-
inch chassis)
1, 2, 3, or 4
Specifies the module's slot number
designated on the chassis.
Enter up to 20
This represents the customer's circuit ID.
characters
The first and last characters must be alpha
or numeric; middle characters can be alpha,
numeric, or hyphens.
Equipped
Establishes communication with MPU.
Module must be set to EQUIPPED before
remaining selections are allowed.
Unequipped
No communication with MPU.
: NOT APPL
: UNIT SWITCH
: DISABLED
: UNIT SWITCH
: 0
: AIS
.
.
.
.
.
.
.
.
.
Span Power: DISABLED
LBO: 7.5
DESCRIPTION
© 2000, ADC Telecommunications, Inc.
DLP-534
Page 2 of 6
minutes
.
.
.
.
dB
6127-C
DEFAULT
1
1
Blank
UNEQUIPPED
(continued)
2-115
Need help?