[Ser - CAB A Series Programming Manual

Thermal / thermal transfer printers
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

PRODUCT MARKING AND BARCODE IDENTIFICATION
[SER:...] - Serial numbering
Causes the printer to print serial numbers.
Syntax:
[SER:start{,incr,{freq}}]
cab printers will use automatically "1" if incr and freq are not set.
J
Example:
S l1;0,0,68,71,100
T:CNT; 10,15,0,3,10;[SER:1][I]
T:FIELD1;10,10,0,3,10;[+:1,CNT][C:0][D:4,0]
T:FIELD2;10,20,0,3,10;[+:1,CNT][C: ][D:4,0]
A 5
The same example as for the "C:Fill.." command has been used
(leading zeroe replacement)
Please see there to get more information about these functions
[TABLE OF CONTENTS] [COMMAND LIST]
cab Produkttechnik GmbH & Co KG
start =
Initialisation value
- sets the start number
incr =
increment value
- presets the number which is added to the start number
freq =
frequency - defines the number of identical values on the
labels before the serialnumber increments.
[ESC] [i] [L] [S]