PRODUCT MARKING AND BARCODE IDENTIFICATION
B - Barcode
Barcode type:
Syntax:
B[:name;]x,y,r,UPCA[+options],height;ne,text CR
[TABLE OF CONTENTS] [COMMAND LIST]
124

UPC-A

UPC-A
Length:
fixed - 12 digits
Valid characters: numeric only
digits: 0-9,
check digits:
yes (Mod 10)
ratio oriented:
no
UPC-A is a retail barcode with a fixed length of 12 digits. The 12th digit is a
modulo 10 check digit. cab printers require only 11 digits. The 12th digit is
calculated by the printer.
[+options] = +WSarea,
White Space area prints quiet zone markers around the bar
code, to make sure that the barcode can be read after printing.
This option is for design purposes only and should be removed
after the label is programmed.
+XHRI,
+XHRI (Extended Human Readable Interpretation) Reduces the
size of the barcode (see the example)
+NOCHECK
suppresses the check digit calculation for variable weight
(UPC-A with specific start numbers :21, 24...29)
Height and narrow element (ne) can be replaced by an SC
value(see example on the next page)
SCx,
sets the size of the barcode to a defined standard code size.
x is a numeric value (0-9) and the possible barcode size
depends on the printer´s resolution. Used instead of height and
ne (narrow element)
[ESC] [i] [L] [S]