Chapter 6, Call Processing Subsystem
The CALL CONTROL Screen

Cntl Channel

[] Connect

NOTE:
126
S:\HP892XX\USRGUIDE\manual\callscrn.fb
This field is used to set the control channel number used by the Test Set.
The
field is an immediate action field. That is, whenever the
Cntl Channel
field is changed, the change is reflected immediately in the
Cntl Channel
physical configuration of the Test Set (the control channel is immediately de-
activated, reconfigured, and then re-activated to reflect the change) and causes an
immediate change to the current state of the Call Processing Subsystem (the state
is set to
).
Active
When lit, the
Connect
to the Test Set on a voice channel.
When the CALL CONTROL screen is displayed and the Call Processing Subsystem is in
the connected state (Connect annunciator is lit), the Test Set constantly monitors the
mobile station's transmitted carrier power. If the power falls below 0.0005 Watts the Test
Set will terminate the call and return to the active state (Active annunciator is lit). The
mobile station's transmitted carrier power is monitored on all Call Processing Subsystem
screens except the ANALOG MEAS screen.
If the Test Set is in the connected state (Connect annunciator is lit) and a
change is made to the Cntl Channel field the connected state will be lost.
annunciator indicates that the mobile station is connected

Hide quick links: