Chapter 8, Signaling Decoder Screen
MPT 1327 Decoder

Manually Decoding MPT 1327 Signals

Decoder Triggering

312
S:\HP892XX\USRGUIDE\manual\decoscrn.fb
To manually test MPT 1327 radios using this decoder, you must first set up the
MPT 1327 Encoder to provide the necessary protocol to get the radio up on the
correct channel. This requires a thorough knowledge of the MPT 1327 Encoder
operation, including using the undisplayed controls accessed using IBASIC
commands.
For these reasons, the following information generally assumes you are operating
the decoder under IBASIC control.
For MPT 1327 signaling detection, the decoder should be configured for
repetitive retriggering using the HP-IB command:
TRIGger:MODE:RETRigger REPetitive
When the decoder is armed it is triggered whenever it receives the
synchronization sequence appropriate to the test mode (selected on the MPT 1327
Encoder screen). Refer to
.
table 7