Originate a Call from a Mobile Station

Using the CALL CONTROL Screen to Test Call Processing Functions
Ensure that the Test Set is in the active state.
Channel" on page 143
1. Connect the mobile station to the Test Set as shown in
bile Station to the Test Set," on page
2. Turn on the mobile station.
3. If the CALL CONTROL screen is not displayed, select CALL CNTL from the To
Screen menu. The CALL CONTROL screen will be displayed.
4. Position the cursor on the Display field and select Data.
5. Dial the desired phone number on the mobile station and press the SEND key on the
mobile station's handset. The mobile station signals the Test Set on the reverse control
channel with an origination message which includes the dialed phone number, the
mobile station's MIN number and the mobile station's ESN. If the mobile station
transmitted properly on the reverse control channel, the message RECC Return will
flash momentarily in the upper right-hand corner of the CALL CONTROL screen and
then the mobile station phone number, ESN, decoded SCM, and the called phone
number will be displayed. The Test Set will then reconfigure itself to the voice channel
assignments set up in the Voice Channel Assignment section of the CALL
CONTROL screen. The Access annunciator will then light while the Test Set signals
the mobile station on the assigned voice channel. The Connect annunciator will light
if the mobile station properly signals the Test Set on the reverse voice channel. The
mobile station is now connected to the Test Set on the assigned voice channel. The left-
hand fields will be replaced with appropriate information.
See "Turn On The Test Set's Control
for information on how to activate the Test Set.